Avoice Regulations

England Approved Document G

May 2024 amendments to Approved Document G: Sanitation, hot water safety and water efficiency

Library captured 10 September 2026 · Source updated 30 September 2024

The Building Regulations 2010

#

Source page 1

Amendments to the Approved Documents

This document contains amendments to the following Approved Document:

Approved Document G: Sanitation, hot water safety and water efficiency 2015 edition incorporating 2016 amendments

May 2024

For use in England

Introduction

#

Source page 2

This document sets out amendments to guidance previously published in Approved Document G: Sanitation, hot water safety and water efficiency, 2015 edition incorporating the 2016 amendments.

These amendments have been incorporated in the online available Approved Document G. Hard copy versions will need to be read alongside the amendments listed in this document. You should always check the online version to know that you are looking at the most up to date version.

The changes highlighted in this amendment booklet take effect on 1 October 2024 for use in England. The previous edition will continue to apply in relation to building work on a particular building where a building notice, an initial notice or an application for building control approval with full plans, has been given to the relevant authority in respect of that building before the day the new regulations come into force, 1 October 2024, and either the building work to which it relates:

a.has started and is sufficiently progressed before that day; or

b.is started and is sufficiently progressed within the period of six months beginning on that day.

Please note that ‘building notice’, ‘initial notice’ and ‘building control approval application with full plans’ have the meanings given in the Building Regulations 2010. For the purpose of these transitional arrangements, building work is to be regarded as ‘sufficiently progressed’:

a.where the building work consists of the construction of a building, when the pouring of concrete for the permanent placement of the trench, pad or raft foundations has started, or the permanent placement of piling has started;

b.where the building work consists of work to an existing building, when that work has started; or

c.where the building work consists of a material change of use of a building, when work to effect that change of use has started.

Full details of the changes are provided below.

The Building Regulations 2010

#

Source page 3

Approved Document G: Sanitation, hot water safety and water efficiency

2015 edition incorporating 2016 amendments

List of amendments

May 2024

G4: Sanitary convenience and washing facilities

Page 29 Replace paragraphs 4.1 to 4.6 inclusive with the following.

4.1Attention is also drawn to the requirements for accessible sanitary conveniences and hand washing facilities of Part M (Access to and use of buildings) of Schedule 1 to the Building Regulations 2010 and to Approved Document M and to the Regulators’ performance specification made under the Water Supply (Water Fittings) Regulations 1999 (SI 1999/1148 as amended) for WC suites.

4.2The requirement T1 for specific types of toilet accommodation in buildings other than dwellings is in Part T (Toilet accommodation) of Schedule 1 to the Building Regulations 2010. Approved Document T provides guidance on how to meet requirement T1 with the provision of the following types of toilet accommodation:

Type A – Fully enclosed self-contained ambulant universal toilet

Type B – Fully enclosed self-contained universal toilet

Type C – Ambulant single-sex toilet cubicle (not self-contained)

Type D – Single-sex toilet cubicle (not self-contained)

4.3Requirement for ventilation is in Part F (Ventilation) of Schedule 1 to the Building Regulations 2010. Guidance on ventilation of sanitary accommodation is given in Approved Document F

4.4The number, type and siting of sanitary conveniences, including separate provision for men and women, for staff in workplaces are also subject to the Workplace (Health, Safety and Welfare) Regulations 1992. Attention is drawn to the Approved Code of Practice issued with respect to those Regulations. Requirement T1 sets a requirement for the provision of specific facilities that should be provided in addition to requirements for general sanitary provision under the Workplace (Health, Safety and Welfare) Regulations 1992.

Scale of provision and layout in buildings other than dwellings

#

Source page 4

4.5Further guidance on washbasins associated with sanitary conveniences may be found in the Food Standards Agency’s Code of Practice _Food hygiene – a guide for businesses_.

4.6Guidance on the selection, installation and maintenance of sanitary appliances including composting toilets may be found in BS 6465-3.

4.7Where hot and cold taps are provided on a sanitary appliance, the hot tap should be on the left.

Scale of provision and layout in buildings other than dwellings

Page 29Replace paragraph 4.11 with the following.

4.12Guidance on the provision of activity space around sanitary appliances is given in BS 6465-2.

Page 30Replace paragraph 4.14 with the following.

4.15Further guidance on the provision of sanitary conveniences can be found in BS 6465-1. This may be used for those building types not set out in paragraph 4.13 above or for those workplaces where the applicant wishes to provide more than the minimum recommended in the Approved Code of Practice, for example, to deliver equivalent provision for men and women. Approved Document T provides guidance on the arrangement of sanitary appliances to meet requirement T1.

Replace paragraph 4.15 with the following.

4.16A sanitary convenience may be provided in:

a.a self-contained room which also contains hand washing facilities;

b.in a cubicle with shared hand washing facilities located in a room containing a number of cubicles; or

c.in a self-contained room with hand washing facilities provided in an adjacent room.

Replace paragraph 4.18 with the following.

4.19Guidance on the provision of activity space around sanitary appliances is given in BS 6465-2.

Page 33Replace paragraph 5.7 with the following.

5.7Guidance on the provision of activity space around sanitary appliances is given in BS 6465-2.

Replace paragraph 5.8 with the following.

5.8The number of fixed baths or showers and washbasins in buildings with rooms for residential purposes should be in accordance with BS 6465-1.

Appendix C — References

#

Source page 5

Replace BS 6465-1:2006 + A1:2009 Sanitary installations. Code of practice for the design of sanitary facilities and scales of provision of sanitary and associated appliances. BSI, 2006 with the following.

BS 6465-1 Sanitary installations. Code of practice for the design of sanitary facilities and scales of provision of sanitary and associated appliances [2006 + A1:2009].

Replace BS 6465-2:1996 Sanitary installations. Code of practice for space requirements for sanitary appliances. BSI, 1996 with the following.

BS 6465-2 Sanitary installations. Space recommendations. Code of Practice for sanitary appliances [2017].

Replace BS 6465-3:2006 Sanitary installations. Code of practice for the selection, installation and maintenance of sanitary and associated appliances. BSI, 2006 with the following.

BS 6465-3 Sanitary installations. Code of practice for the selection, installation and maintenance of sanitary and associated appliances [2020].

List of Approved Documents

#

Source page 6

The following documents have been published to give guidance on how to meet the Building Regulations. You can find the date of the edition approved by the Secretary of State at www.gov.uk.

Approved Document A Structure

Approved Document B Fire safety Volume 1: Dwellings

Approved Document B Fire safety Volume 2: Buildings other than dwellings

Approved Document C Site preparation and resistance to contaminants and moisture

Approved Document D Toxic substances

Approved Document E Resistance to the passage of sound

Approved Document F Ventilation Volume 1: Dwellings

Approved Document F Ventilation Volume 2: Buildings other than dwellings

Approved Document G Sanitation, hot water safety and water efficiency

Approved Document H Drainage and waste disposal

Approved Document J Combustion appliances and fuel storage systems

Approved Document K Protection from falling, collision and impact

Approved Document L Conservation of fuel and power Volume 1: Dwellings

Approved Document L Conservation of fuel and power Volume 2: Buildings other than dwellings

Approved Document M Access to and use of buildings Volume 1: Dwellings

Approved Document M Access to and use of buildings Volume 2: Buildings other than dwellings

Approved Document O Overheating

Approved Document P Electrical safety – Dwellings

Approved Document Q Security – Dwellings

Approved Document R Infrastructure for electronic communications Volume 1: Physical infrastructure and network connection for new dwellings

Approved Document R Infrastructure for electronic communications Volume 2: Physical infrastructure for high-speed electronic communications networks

Approved Document S Infrastructure for the charging of electric vehicles

Approved Document T Toilet accommodation

Approved Document 7 Materials and workmanship

Page 7

#

Source page 7

The Building Regulations 2010, Approved Documents are available from:

RIBA Books Online: www.ribabooks.com Telephone: (0)207 307 5355 Email: sales@ribabooks.com

© Crown copyright, 2024

You may re-use this information (excluding logos) free of charge in any format or medium, under the terms of the Open Government Licence v3.

To view this licence, visit www.nationalarchives.gov.uk/doc/open-government-licence/version/3/ or write to the Information Policy Team, The National Archives, Kew, London TW9 4DU or email psi@nationalarchives.gsi.gov.uk.

Where we have identified any third-party copyright information, you will need to obtain permission from the copyright holders concerned. This publication is available for download at www.gov.uk.

Copyright in the typographical arrangement, excluding logos, of the cover and internal page layouts of this publication rests with the publisher.

Your next step

Meet your mini assistant.

Sign up to ask questions about Building Regulations and explore the guidance with Avoice.

Sign up

Already have an account? Log in

Already an Avoice customer? Log in