Avoice generates a full Uniclass specification from your drawings: Reviewed, cross-referenced, and ready to issue.
Ss_25_10_30
Internal walls — blockwork
Ss_25_10_30 /1.0 Products
1. Concrete blocks: Aggregate concrete blocks to BS EN 771-3, minimum compressive strength 7.3 N/mm². 85%
2. Block density and thickness: ✓ COMPLETE 90%
2.1 Dense concrete, minimum 1900 kg/m³ for walls requiring fire resistance.
2.2 Lightweight aggregate, maximum 1400 kg/m³ elsewhere.
2.3 Thickness: 100mm non-fire-rated, 140mm fire-rated. Refer to drawings for wall type schedule.
3. Movement joints: compressible filler board, 13mm wide, with sealant to match. ○ SEALANT NOT SPECIFIED 55%
4. Fire resistance requirements not yet specified. § AWAITING FIRE STRATEGY 0%
72% complete
4 gaps · 2 critical
View all issues →
Every conflict. Found automatically.
Avoice reads your drawings, scans your schedules, and flags every conflict, mismatch, and missing detail across your specification — before it reaches the contractor.

Cross-reference check

Spec vs Drawings vs Schedules
4 issues found
CONFLICT Block thickness — spec vs drawing
SPECSs_25_10_30 /100
140mm to fire-rated walls
140mm
DRAWINGA-201 Rev P03
Wall W04 (corridor): shown as 100mm
100mm
Wall thickness · Detected today
CONFLICT Door schedule contradicts fire strategy
SCHEDULEDoor Sched Rev B
D-14 to D-22 corridor doors: FD30
FD30
FIRE STRATEGYRev D §5.1.3
All corridor doors: FD60S + smoke seals
FD60S
Fire doors · Detected today
MISMATCH DTM decision not reflected in spec or drawings
SPEC + DWGSs_25_10_60
Insulation: 100mm PIR board
100mm
DTM #1427 Mar
Increased to 120mm for Part L
120mm
Insulation · 2 days ago
MISSING No drawing for blockwork-to-curtain wall junction
SPECSs_25_10_30
DPC where blockwork abuts external walls
Required
DRAWINGNone found
No junction detail — site issue at grid 4
Missing
Junction detail · 3 days ago
Specs built from your project, not a template.
GA plans, consultant reports, employer's requirements, door schedules — Avoice ingests your project documents and generates a coordinated Uniclass specification. Every clause grounded in your drawings. Every cross-reference checked.
Drop project documents
PDF, DWG, XLS, IFC
DWG
GA_Plans_A100-A110_RevP03.dwg
12.4 MB
PDF
Fire_Strategy_RevD_HoareLea.pdf
2.4 MB
PDF
Acoustic_Report_BB93_SandyBrown.pdf
1.8 MB
XLS
Door_Schedule_RevB.xlsx
320 KB
PDF
Employers_Requirements_DfE.pdf
4.1 MB
DWG
Structural_GA_S201-S204.dwg
8.6 MB
Every conflict. Found automatically.
Avoice reads your drawings, scans your schedules, and flags every conflict, mismatch, and missing detail across your specification — before it reaches the contractor.

Cross-reference check

Spec vs Drawings vs Schedules
4 issues found
CONFLICT Block thickness — spec vs drawing
SPECSs_25_10_30 /100
140mm to fire-rated walls
140mm
DRAWINGA-201 Rev P03
Wall W04 (corridor): shown as 100mm
100mm
Wall thickness · Detected today
CONFLICT Door schedule contradicts fire strategy
SCHEDULEDoor Sched Rev B
D-14 to D-22 corridor doors: FD30
FD30
FIRE STRATEGYRev D §5.1.3
All corridor doors: FD60S + smoke seals
FD60S
Fire doors · Detected today
MISMATCH DTM decision not reflected in spec or drawings
SPEC + DWGSs_25_10_60
Insulation: 100mm PIR board
100mm
DTM #1427 Mar
Increased to 120mm for Part L
120mm
Insulation · 2 days ago
MISSING No drawing for blockwork-to-curtain wall junction
SPECSs_25_10_30
DPC where blockwork abuts external walls
Required
DRAWINGNone found
No junction detail — site issue at grid 4
Missing
Junction detail · 3 days ago
Production-ready specs without the enterprise bill.
No software should have a monopoly on spec writing. We're here to make it fast, accurate, and accessible to every firm.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
z
z
z
z
i
i
z
z
From workload to workflow
Try the AI workspace built for architecture.