Part L · England · Free to use

Limiting U-values check (Part L)

Check walls, roofs, floors, windows and doors against the limiting fabric values in Tables 4.1 and 4.2.

Approved Document L Volume 1 (2021, including 2023 amendments)

Your inputs

Results update as you type.

Work
W/m²K
W/m²K
W/m²K
W/m²K
W/m²K
W/m²K

Part L · Result

1 element over the limit

New and replacement elements in existing homes. Windows may instead meet WER Band B, doors DSER Band B or C.

Check failed
  • External wall: Checks passedmax 0.180.18
  • Roof: Checks passedmax 0.150.15
  • Floor: Checks passedmax 0.180.18
  • Windows: Checks passedmax 1.41.4
  • Rooflights: Checks passedmax 2.22.2
  • Doors: Check failedmax 1.41.6
  • Renovated elements use the Table 4.3 threshold and improved values instead.

Clauses this relies on

Source edition and scope

Approved Document L Volume 1 (2021, including 2023 amendments).

Uses the 2021 edition including 2023 amendments. These are limiting values, not a calculation of a construction’s U-value or the dwelling’s overall energy performance. Check the applicable standards and transition dates for your project.

This is a preliminary check of the conditions shown. Confirm the edition, project circumstances and any additional requirements with your architect or building control.

A design aid, not legal advice. Checked against the Building Regulations 2010 for England; confirm with building control.