Part M · England · Free to use

M4(2) and M4(3) dimensions checker

Check door widths, corridors, approach route and turning space against the accessible and wheelchair dwelling categories.

Approved Document M Volume 1 (2015, including 2016 amendments)

Your inputs

Results update as you type.

Category
mm
mm
mm
mm
Approach to that door
mm

Part M · Result

Meets M4(2) dimensions checked

A dimensions check only. Bathrooms, kitchens, lifts and services have further rules.

Checks passed
  • Approach route width: Checks passedmin 900 mm (para 2.9)900 mm
  • Approach route gradient: Checks passedbetween 1:20 and 1:12 (para 2.10)1:15
  • Entrance door clear width: Checks passedmin 850 mm (para 2.20)850 mm
  • Hall and landing width: Checks passedmin 900 mm (para 2.22)1,050 mm
  • Door against corridor: Checks passed775 mm door, not head-on: corridor min 1050 mm (Table 2.1)1,050 mm
  • A standard 826 mm leaf up to 44 mm thick counts as 775 mm clear (Table 2.1 note 3).
  • M4(3) level-access shower: 1,200 × 1,200 mm (1,000 × 1,000 mm in a WC or cloakroom).

Clauses this relies on

Source edition and scope

Approved Document M Volume 1 (2015, including 2016 amendments).

This is a preliminary check of the conditions shown. Confirm the edition, project circumstances and any additional requirements with your architect or building control.

A design aid, not legal advice. Checked against the Building Regulations 2010 for England; confirm with building control.