Part B · England · Free to use

Fire resistance periods

Minimum period of fire resistance for the structure by purpose group, sprinklers and height of the top storey.

Approved Document B Volume 2 (2026 PDF; table values effective until September 2029)

Your inputs

Results update as you type.

Sprinklers throughout
m
Basement

Part B · Result

60 minutes fire resistance

Sprinklered flats, top storey 16.8 m above ground.

Calculated result
  • Elements of structure, above ground: Calculated resultup to 18 m60 minutes
  • Flats with a top storey over 11 m need sprinklers anyway (Vol 1 para 7.4).
  • Compartment walls separating buildings: at least 60 minutes. Elements protecting means of escape: at least 30 minutes.
  • Purpose groups 3 to 7(a) with a top storey over 30 m need sprinklers.

Clauses this relies on

Source edition and scope

Approved Document B Volume 2 (2026 PDF; table values effective until September 2029).

This is a preliminary check of the conditions shown. Confirm the edition, project circumstances and any additional requirements with your architect or building control.

A design aid, not legal advice. Checked against the Building Regulations 2010 for England; confirm with building control.