BSA · England · Free to use

Higher-risk building checker

Is it a higher-risk building under the Building Safety Act, and which height-based fire measures apply to a block of flats.

Building Safety Act 2022, SI 2023/275, and Approved Document B Volume 1 (2026)

Your inputs

Results update as you type.

m

Ignore basements and galleries under 50% of the floor below (Reg 6).

BSA · Result

Not a higher-risk building

Below 18 m and 7 storeys.

Checks passed
  • 18 m or 7 storeys: Checks passed16.8 m, 6 storeysNo
  • At least 2 residential units, or care home or hospital: Calculated resultYes
  • Excluded description: Calculated resulthotel, secure residential, militaryNo
  • Higher-risk building (design and construction): Checks passedBSA s.65, SI 2023/275No
  • Sprinklers throughout: Check neededtop storey over 11 m (Vol 1 para 7.4)Required
  • Floor and flat wayfinding signage: Check neededtop storey over 11 m (para 15.13)Required
  • Secure information box: Check neededtop storey over 11 m (para 15.19)Required
  • Second common stair: Checks passedtop storey 18 m or more (para 3.30)Not triggered
  • Evacuation alert system to BS 8629: Checks passedtop storey over 18 m (para 15.17)Not triggered
  • Height is measured from ground level to the top of the floor surface of the top storey, ignoring rooftop plant (Reg 5).
  • The occupation regime (Reg 8) additionally excludes care homes and hospitals.

Clauses this relies on

Source edition and scope

Building Safety Act 2022, SI 2023/275, and Approved Document B Volume 1 (2026).

This is a preliminary check of the conditions shown. Confirm the edition, project circumstances and any additional requirements with your architect or building control.

A design aid, not legal advice. Checked against the Building Regulations 2010 for England; confirm with building control.